Exadata X6 / X8 Disk replacement

 Exadata X6 / X8 Disk replacement

-- Login to storage cell and check Alert histroy

[root@Server300SC03-man ~]# cellcli

CellCLI> list alerthistory

         5_1     2021-07-03T02:22:42+02:00       critical        "Data hard disk failed.  Status        : FAILED  Manufacturer  : WDC  Model Number  :     W7214A520ORA014T  Size          : 14TB  Serial Number : 2042NB976T  Firmware      : A144  Slot Number   : 6  Cell Disk     : CD_06_Server300SC03_man  Grid Disk     : CATALOG_CD_06_Server300SC03_man, DELTA_CD_06_Server300SC03_man"

         5_2     2021-07-03T08:00:42+02:00       warning         "Oracle Exadata completed the rebalance operation triggered by dropping the following ASM disks: ASM Disk Names       : CATALOG_CD_06_Server300SC03_MAN, DELTA_CD_06_Server300SC03_MAN  ASM Diskgroups       : CATALOG, DELTA  Grid Disks           : CATALOG_CD_06_Server300SC03_man, DELTA_CD_06_Server300SC03_man  Cell Disk            : CD_06_Server300SC03_man  Physical Disk        : 252:6  Physical Disk Status : failed "

         5_3     2021-08-19T11:06:38+02:00       warning         "Data hard disk was removed.  Status        : NOT PRESENT  Manufacturer  : WDC  Model Number  :     W7214A520ORA014T  Size          : 14TB  Serial Number : 2042NB976T  Firmware      : A144  Slot Number   : 6  Cell Disk     : CD_06_Server300SC03_man  Grid Disk     : CATALOG_CD_06_Server300SC03_man, DELTA_CD_06_Server300SC03_man"

         5_4     2021-08-19T11:10:12+02:00       warning         "Data hard disk was replaced.  Status        : NORMAL  Manufacturer  : WDC  Model Number  :     W7214A520ORA014T  Size          : 14TB  Serial Number : 2111NVKBWL  Firmware      : A144  Slot Number   : 6  Cell Disk     : CD_06_Server300SC03_man  Grid Disk     : CATALOG_CD_06_Server300SC03_man, DELTA_CD_06_Server300SC03_man"

CellCLI> list griddisk attributes name,status,asmmodestatus,asmdeactivationoutcome

         CATALOG_CD_00_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_01_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_02_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_03_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_04_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_05_Server300SC03_man    proactive failure  DROPPED  Yes

         CATALOG_CD_06_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_07_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_08_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_09_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_10_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_11_Server300SC03_man    active  ONLINE  Yes

         DELTA_CD_00_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_01_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_02_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_03_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_04_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_05_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_06_Server300SC03_man      proactive failure  DROPPED  Yes

         DELTA_CD_07_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_08_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_09_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_10_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_11_Server300SC03_man      active  ONLINE  Yes

CellCLI> list physicaldisk

         252:0           NJBSNT                  normal

         252:1           NRKGNT                  normal

         252:2           NNRX7T                  normal

         252:3           NMWTHT                  normal

         252:4           N37D0L                  normal

         252:5           NRDZ4T                  normal

         252:6           NVKBWL                  dropped

         252:7           NU6SBT                  normal

         252:8           NPVLHT                  normal

         252:9           N4GS4L                  normal

         252:10          NRZZAT                  normal

         252:11          NRH57T                  normal

         FLASH_10_1      PHLN0436007R6P4EGN-1    normal

         FLASH_10_2      PHLN0436007R6P4EGN-2    normal

         FLASH_5_1       PHLN044000HJ6P4EGN-1    normal

         FLASH_5_2       PHLN044000HJ6P4EGN-2    normal

         M2_SYS_0        PHYH0246032B240J        normal

         M2_SYS_1        PHYH02440190240J        normal


CellCLI> list physicaldisk 252:6 detail

         name:                   252:6

         deviceId:               12

         deviceName:             /dev/sdg

         diskType:               HardDisk

         enclosureDeviceId:      252

         errOtherCount:          0

         luns:                   0_6

         makeModel:              "WDC W7214A520ORA044T"

         physicalFirmware:       A144

         physicalInsertTime:     2021-08-19T11:10:06+02:00

         physicalInterface:      sas

         physicalSerial:         NVKBWL

         physicalSize:           12.474609375T

         slotNumber:             6

         status:                 warning - predictive failure


CellCLI> alter physicaldisk 252:6 drop for replacement

CellCLI> list physicaldisk 20:3 detail

         name:                   20:3

         deviceId:               21

         diskType:               HardDisk

         enclosureDeviceId:      20

         errMediaCount:          14

         errOtherCount:          0

         makeModel:              "SEAGATE ST32000SSSUN2.0T"

         physicalFirmware:       061A

         physicalInsertTime:     2014-06-30T14:15:33+00:00

         physicalInterface:      sas

         physicalSerial:         L2KDFT

         physicalSize:           1863.0166854858398G

         slotNumber:             3

         status:                 warning - predictive failure - dropped for replacement

-- Oracle Field Engineer can safely replace the disk.

remove the faulty disk - wait for 3min and then insert the new disk

CellCLI> list physicaldisk

         252:0           NJBSNT                  normal

         252:1           NRKGNT                  normal

         252:2           NNRX7T                  normal

         252:3           NMWTHT                  normal

         252:4           N37D0L                  normal

         252:5           NRDZ4T                  normal

         252:6           NVKBWL                  normal

         252:7           NU6SBT                  normal

         252:8           NPVLHT                  normal

         252:9           N4GS4L                  normal

         252:10          NRZZAT                  normal

         252:11          NRH57T                  normal

         FLASH_10_1      PHLN0436007R6P4EGN-1    normal

         FLASH_10_2      PHLN0436007R6P4EGN-2    normal

         FLASH_5_1       PHLN044000HJ6P4EGN-1    normal

         FLASH_5_2       PHLN044000HJ6P4EGN-2    normal

         M2_SYS_0        PHYH0246032B240J        normal

         M2_SYS_1        PHYH02440190240J        normal


CellCLI> list physicaldisk 252:6 detail

         name:                   252:6

         deviceId:               12

         deviceName:             /dev/sdg

         diskType:               HardDisk

         enclosureDeviceId:      252

         errOtherCount:          0

         luns:                   0_6

         makeModel:              "WDC W7214A520ORA044T"

         physicalFirmware:       A144

         physicalInsertTime:     2021-08-19T11:10:06+02:00

         physicalInterface:      sas

         physicalSerial:         NVKBWL

         physicalSize:           12.474609375T

         slotNumber:             6

         status:                 normal


CellCLI> list griddisk attributes name,status,asmmodestatus,asmdeactivationoutcome

         CATALOG_CD_00_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_01_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_02_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_03_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_04_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_05_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_06_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_07_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_08_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_09_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_10_Server300SC03_man    active  ONLINE  Yes

         CATALOG_CD_11_Server300SC03_man    active  ONLINE  Yes

         DELTA_CD_00_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_01_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_02_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_03_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_04_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_05_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_06_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_07_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_08_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_09_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_10_Server300SC03_man      active  ONLINE  Yes

         DELTA_CD_11_Server300SC03_man      active  ONLINE  Yes


Comments